Create amazing spaces of unsurpassed beauty and character with high-performance sound reduction with TerraMai’s new Acoustic Panels designed for wall and ceiling applications. Panels come complete with acoustic insulation and install easily on industry-standard ceiling and wall systems.
Species: Acacia, Amish White Oak, Angelique, Doug Fir, Orchard Walnut, Rock Walnut
Net Dimensions: 2-1/4" (57mm) thick x 12" (305mm) wide x 95-7/8" (2435mm) long. If specifying 2" thick acoustic insulation, increase overall panel thickness by 1" (25mm).
Construction: Six 1-1/4” (32mm) wide x 1-1/4” (32mm) deep x 95-7/8" (2435mm) long slats spaced 3/4” (19mm) apart installed on nine 1-1/2" (32mm) x 1" (25mm) x 12" (305mm) Doug Fir rails stained black with low-VOC stain. Rows of slats may be made up of multiple pieces, up to 1 butt joint per row (may be custom ordered with full length slats). 1" or 2" thick black acoustic insulation bonded to back between rails.
Millwork: S4S square edge
Finish: Zero-VOC oil or low-VOC poly - Treated with Class A Fire Retardant on best faces
Character: Varies by species. See chart below for details.
Species |
Character |
Acacia |
Mixed grain and color variation with very occasional prefilled holes. |
Amish White Oak |
Mixed grain. Surface seasoning checks. Sound and missing knots. |
Angelique |
Very clean with an occasional pin knot. |
Doug Fir |
May include sound tight, loose, or missing knots of all sizes. Surface seasoning checks. |
Orchard Walnut |
Mixed grain with sound, tight, and missing knots, and occasional surface seasoning checks. |
Rock Walnut |
Mixed grain with occasional small sound, tight knots. |
Certifications: FSC Mix 0% to 87% depending on species - FSC-C021798
Acoustic Performance:
|
Acoustic Insulation Thickness |
SAA
(Sound Absorption Average) |
NRC
(Noise Reduction Coefficient) |
Ceilings* |
2" |
0.92 |
0.90 |
1" |
0.85 |
0.85 |
Walls** |
2" |
0.91 |
0.90 |
1" |
0.72 |
0.70 |
* Testing performed by an accredited 3rd party lab in accordance with ASTM C423 using E-400 Mount
** Testing performed by an accredited 3rd party lab in accordance with ASTM C423 using A-Mount